X2 – Series
Reverse Osmosis System


Product Images

X2 – SERIES REVERSE OSMOSIS (RO) SYSTEM

The AXEON X2 – Series is designed to be a cost–effective reverse osmosis (RO) system for light industrial, 8” membrane applications with a capacity of 30 gallons per minute (GPM) or 43,200 gallons per day (GPD).

The X2 – Series system is a mid-range model designed for OEMs and distributors servicing the water treatment industry. Certain models come with options from a select list of add–ons and upgrades, although some of the options are not included on this model.

The X2 – Series systems come pre–assembled and pre–wired for ease of installation and servicing. The simple design of the X2 – Series systems make them easy to use, cost effective and reliable water purification systems.

The X2 – Series systems are designed to treat brackish feedwater sources drawn from well water with total dissolved solids (TDS) levels of 7,000 ppm. The X2 – Series are built with SS Schedule 40 piping on the high pressure side. The equipment and components are recommended not to exceed the maximum operating pressure of 400 psi.


Design Parameters
Configuration Single Pass
Inlet Pressure Minimum / Maximum (PSI) 45 / 85
Design Feedwater Temperature (°F / °C) 77 / 25
Feedwater Source** Product Flow rate for each model based on a nominal TDS of 7,000 ppm
Nominal Pre – Filtration Requirements 5 Micron Nominal
Feedwater Silt Density Index (SDI) < 3
Nominal Membrane Salt Rejection (%) 99.8
Nominal System Recovery (%) 58 – 73

**Treatment ability of the reverse osmosis system is dependent on feedwater quality. Performance projections must be run for each installation.

Feedwater Requirements***
Maximum SDI Rating < 3
Maximum Turbidity 1 NTU
Maximum Free Chlorine and/or Chloramines 0 ppm
pH (Continuous) 2 – 11
pH (Cleaning for 30 minutes) 1 – 13
Environment Parameters
Min Ambient Temperature °F (°C) 40 (4.4)
Max Ambient Temperature °F (°C) 120 (48.9)
Operating Parameters***
Feed Temperature °F (°C) 50 to 85 (10 to 30)
System Inlet Pressure (PSI) 45 to 85
Maximum Operating Pressure (PSI) 400
Regulations and Standards
Frame Welding Plant standard
Seismic Rating None
Piping Unit is fully tested for normal operation and conditions

***If any of the feedwater parameters are not within the limits given, consult Application Engineering for assistance.

SPECIFICATIONS
System Production Flow Rate Specifications (GPM)
Model Number X2–3280
Feed (Maximum) 70
Permeate (Maximum) 30
Concentrate (Minimum) 16
Unit Configuration Specifications
Model Number X2–3280
Vessel Array 1:1:1
Vessel Quantity 3
Membrane Quantity 6
Model Number X2–3280
Frame
Materials 304 Stainless Steel
Paint N/A
Color N/A
Pump
Manufacturer Grundfos
Model CRN15-17 A-FGJ-G-E-HQQE
Materials 316 Stainless Steel
Connection Type 2” Flange
Pump Motor
Manufacturer Grundfos
Type TEFC
RPM@60Hz 2900
Power (Hp) 20
Rated Voltage 380-415D / 660-690Y VAC
FLA 28-26 / 16.2-15.6
Phase/Hz 3/50
Membranes
Manufacturer FILMTEC
Model HRLE–440
Materials Polyamide Composite
Pressure Vessels
Supplier Protec Arisawa
Model PRO–8–450–SP–USA
Materials Fiberglass
Rating 450 PSI Non–ASME Code Stamped
Permeate Connection 1–1/2 Sanitary
Concentrate Connection 1–1/2″ and 2” Victaulic
Piping Systems
Feed Schedule 80 PVC
High Pressure Schedule 40 SS
Permeate Sanitary 316L SS
Prefilter Housings
Manufacturer Shelco
Model 4FOS3
Size 4X (2.5” X 30”)
Material 316 SS
Prefilter
Manufacturer AXEON
Model SDF–25–3005
Media Polypropylene Fibers
Micron Rating 5
Automatic Process Valves
Feed Valve AXEON
Manual Valves
Concentrate Throttling 1″ Globe Valve 316SS
Pump Throttling N/A
Pressure
Pump Pressure Gauge 2–1/2″, Liquid Filled, SS Case with Brass Wetted Parts, 0–600 PSI
Concentrate Pressure Gauge 2–1/2″, Liquid Filled, SS Case with Brass Wetted Parts, 0–600 PSI
Filter Inlet Gauge 2–1/2″, Liquid Filled, SS Case with Brass Wetted Parts, 0–100 PSI
Filter Outlet Gauge 2–1/2″, Liquid Filled, SS Case with Brass Wetted Parts, 0–100 PSI
Low Feed Pressure Switch 15 PSI, 1/4″ FNPT
High Feed Pressure Switch 300–1200 PSI, 1/4″ FNPT
Flow
Permeate Flow Indicator 4 -100 GPM Digital, Flow Meter, Construction, 1.5″ Sanitary Connections
Concentrate Flow Indicator 4 – 40 GPM Digital, Flow Meter, Acrylic Construction, 1.5″ MNPT Connections
Skid Process Connection Specifications
Feed Inlet 2″ FNPT
Permeate Outlet 1–1/2″ Sanitary
Concentrate Outlet 1–1/2″ FNPT
CIP Connections 1–1/2″ FNPT
Chemical Feed Port 1/2” NPT
Skid Physical Dimensions Specifications1
Depth (in) 35
Width (in) 112
Height (in) 74
Shipping Weight (lbs) 2800

1 Does not include operating space requirements.

Skid Process Connection Specifications
Feed Inlet 2″ FNPT
Permeate Outlet 1.5”” Sanitary
Concentrate Outlet 1–1/2″ FNPT
CIP Connections 1.5″ FNPT
Chemical Feed Port 1/2” NPT
Skid Physical Dimensions Specifications1
Depth (in) 41
Width (in) 194
Height (in) 78
Shipping Weight (lbs) 4150

1 Does not include operating space requirements.