Ultraviolet Water Disinfection Systems


Product Images

VT1, VT4, & S2Q-PA

Ultraviolet Water Disinfection Systems

The quality of drinking water can change with time and become contaminated with harmful bacteria. TheTAP family of compact UV disinfection systems provide a reliable, economical, and chemical-free way to safeguard drinking water in any residential application. VIQUA’s products have been designed and tested to ensure quality drinking water is at everyone’s finger tips.

Regardless of your need, there is a VIQUA system to suit your requirements. VIQUA offers systems that range in flow rates from just 1 GPM (0.25 m3/hr) for a single faucet up to 3.5 GPM (0.8 m3/hr) for a small home or cottage.


Features of VIQUA UV water disinfection systems

  • Equipped to inactivate chlorine-resistant parasites such as Cryptosporidium and Giardia, harmful bacteria like E.Coli, and viruses not visible to the naked eye.
  • Specially designed and tested Sterilume™-EX lamps provide consistent and reliable ultraviolet output over the entire life of the lamp (9000 hours) to ensure continuous purification.
  • Safety-Loc™ connector with interlock that ensures power is disconnected before lamp can be removed, hidden ground wire.
  • The system is easy to maintain and service.
  • Built with a durable stainless steel chamber to prolong life and eliminate ultraviolet light degradation.
  • The power supply features an LED power/lamp on indicator.

Specifications

 
MODELS VT1; VT1/2; VT1/2A; VT1/2B VT4; VT4/2; VT4/2A; VT4/2B S2Q-PA; S2Q-PA/2; S2Q-PA/2A; S2Q-PA/2B
FLOW RATES (@ 95% UVT)
US Public Health (16 mJ/cm2) 2 GPM (8 lpm) (0.5 m3/hr) 6.5 GPM (24 lpm) (1.4 m3/hr) 5 GPM (18 lpm) (1.1 m3/hr)
VIQUA Standard (30 mJ/cm2) 1 GPM (4 lpm) (0.25 m3/hr) 3.5 GPM (13 lpm) (0.8 m3/hr) 3 GPM (11 lpm) (0.7 m3/hr)
NSF/EPA (40 mJ/cm2) 0.7 GPM (3 lpm) (0.2 m3/hr) 2.5 GPM (9 lpm) (0.6 m3/hr) 2 GPM (8 lpm) (0.4 m3/hr)
DIMENSIONS
Chamber 12.5” x 2.5” (31.75 cm x 6.5 cm) 17” x 2.5” (43.6 cm x 6.5 cm) 17” x 2.5” (43.6 cm x 6.5 cm)
Controller 12 1/2” x 2 1/2” (31.8 cm x 6.5 cm) 15” x 2 1/2” (38 cm x 6.5 cm) 15” x 2 1/2” (38 cm x 6.5 cm)
Inlet/Outlet Port Size 3/8” FNPT / 1/2” MNPT* 1/2” MNPT* 1/2” MNPT*
Shipping Weight 4 lbs (1.8 kg) 6.5 lbs (2.8 kg) 7 lbs (3.2 kg)
ELECTRICAL
Voltage 100-140V 100-140V 100-140V
Voltage (/2, /2A, /2B) 200-240V 200-240V 200-240V
Power Consumption 13 W 20 W 22 W
Maximum Operating Pressure 125 psi (8.62 bar) 125 psi (8.62 bar) 125 psi (8.62 bar)
Influent Water Temperature 2-40°C (36-104°F) 2-40°C (36-104°F) 2-40°C (36-104°F)
FEATURES
Visual “Power On” YES YES YES
Chamber Material 304 SS 304 SS 304 SS
Visual Lamp Life Remaining NO NO YES
Audible Lamp Failure NO NO YES
Audible Lamp Replacement Reminder NO NO YES

* /2B - BSP

Replacement Parts

S212RL – UV lamp for VT1 BA-VT – controller for VT1 & VT4
S330RL – UV lamp for VT4 & S2Q-PA BA-VT/2 – controller for VT1/2 & VT4/2
QS-212 – quartz sleeve for VT1 BA-VT/2A – controller for VT1/2A & VT4/2A
QS-330 – quartz sleeve for VT4 & S2Q-PA BA-VT/2B – controller for VT1/2B & VT4/2B
410867 – o-ring for quartz sleeve BA-ICE-S – controller for S2Q-PA

Water Quality Parameters

Hardness Iron Tannins
< 7 grains (120 mg/L) < 0.3 mg/L < 0.1 mg/L

THE RIGHT SOLUTION FOR YOU