Industrial Reverse
Osmosis System
Product Images
FEATURES
- 8-inch Low Energy Membrane Elements
- 8-inch Fiberglass Membrane Housings with 316L Stainless Steel Side Ports (450 psi)
- 5-Micron Sediment Filters
- Multi-Cartridge 316L Stainless Steel Cartridge Housing
- Vertical 316L Stainless Steel Multi-Stage Pump
- Low and High Pressure Shut-Off Switches
- S –150 Pre-Programmed Computer ControllerA
- S – 200 Pre-Programmed Computer Controller with VFD (Variable Frequency Drive)B
- Permeate and Concentrate RotametersA
- Permeate and Concentrate Digital Paddlewheel SensorsB
- Feed and Permeate TDS Monitoring
- Pre- and Post-Filter 316L Stainless Steel Pressure Gauges
- Pump Pressure and Concentrate 316L Stainless Steel Pressure Gauges
- Composite Feed Solenoid ValveA
- PVC Feed Motorized Ball ValveB
- 316L Stainless Steel Globe Throttling Valve
- 316L Stainless Steel Globe Concentrate Valve
- Powder Coated Carbon Steel Frame
- Sch80 Low Pressure PVC Piping
- Stainless Steel High Pressure 316L Piping
- Clean-In-Place (CIP) Ports with Valves
- Permeate Sample Valves
- Chemical Feed Ports
- Chemical Feed Power Outlet
- 460 VAC 3PH 60Hz
OPTIONS AND UPGRADES
- S – 200 Computer ControllerC
- VFDC
- Programmable Logic Controller (PLC) with Touch Screen
- Permeate and Concentrate Digital Paddlewheel SensorsC
- PVC Feed Motorized Ball ValveC
- PVC Permeate Divert Motorized Ball Valve
- Permeate Flush
- pH Sensor
- ORP Sensor
- Clean-In-Place (CIP) Skid Mounted System
- Chemical Feed System
- Voltage Options: 220VAC 3PH 60Hz, 220VAC 3PH 50Hz, 380VAC 3PH 50Hz
- A. Standard on Models X2– 2280, X2– 3280, X2– 4280, X2– 5280.
- B. Standard on Models X2– 3480, X2– 4480, X2– 5480, X2– 6480.
- C. Option available for Models X2– 2280, X2– 3280, X2– 4280, X2– 5280. Standard on larger models
Notes:
- 1. All dimensions are given in inches.
- 2. Dimensions given for X2– 2280 through X2– 5280. (X2– 5280 pictured)
Notes:
- 1. All dimensions are given in inches.
- 2. Dimensions given for X2– 3480 through X2– 6480. (X2– 6480 pictured)
SPECIFICATIONS
MODELS | X2– 2280 | X2– 3280 | X2– 4280 | X2– 5280 | X2– 3480 | X2– 4480 | X2– 5480 | X2– 6480 |
---|---|---|---|---|---|---|---|---|
Design | ||||||||
Configuration | Single Pass | Single Pass | Single Pass | Single Pass | Single Pass | Single Pass | Single Pass | Single Pass |
Feedwater TDS max (ppm)D | 7,000 | 7,000 | 7,000 | 7,000 | 7,000 | 7,000 | 7,000 | 7,000 |
Standard Recovery % | 58 | 70 | 73 | 73 | 73 | 70 | 70 | 73 |
Rejection and Flow RatesE | ||||||||
Nominal Salt Rejection % | 99.8 | 99.8 | 99.8 | 99.8 | 99.8 | 99.8 | 99.8 | 99.8 |
Permeate Flow Rate (gpm / lpm) | 21.00 / 79.50 | 31.50 / 119.00 | 42.00 / 159.00 | 52.50 / 198.70 | 63.00 / 238.40 | 84.00 / 318.00 | 105.00 / 397.00 | 126.00 / 477.00 |
Minimum Concentrate Flow Rate (gpm / lpm) | 15 / 57 | 13.5 / 51 | 15.3 / 58 | 19.42 / 73.51 | 23.3 / 88.20 | 36 / 136 | 45 / 170 | 46.6 / 176.40 |
Connections | ||||||||
Feed FNPT (in) | 2 FNPT | 2 FNPT | 2 FNPT | 2 FNPT | 3 FNPT | 3 FNPT | 3 FNPT | 3 FNPT |
Permeate Tubing (in) | 1 1/2 FNPT | 1 1/2 FNPT | 2 FNPT | 2 FNPT | 2 1/2 FNPT | 2 1/2 FNPT | 3 FNPT | 3 FNPT |
Concentrate Connection (in) | 1 1/4 FNPT | 1 1/4 FNPT | 1 1/4 FNPT | 1 1/4 FNPT | 1 1/2 FNPT | 1 1/2 FNPT | 2 FNPT | 2 FNPT |
Clean–in–Place Port (in) | 1 1/2 FNPT | 1 1/2 FNPT | 1 1/2 FNPT | 1 1/2 FNPT | 2 FNPT | 2 FNPT | 2 FNPT | 2 FNPT |
Chemical Feed Port (in) | 1/2 NPT | 1/2 NPT | 1/2 NPT | 1/2 NPT | 1/2 NPT | 1/2 NPT | 1/2 NPT | 1/2 NPT |
Membranes | ||||||||
Membranes Per Vessel | 2 | 2 | 2 | 2 | 4 | 4 | 4 | 4 |
Membrane Quantity | 4 | 6 | 8 | 10 | 12 | 16 | 20 | 24 |
Membrane Size | 8040 | 8040 | 8040 | 8040 | 8040 | 8040 | 8040 | 8040 |
Vessels | ||||||||
Vessel Array | 1:1 | 1:1:1 | 2:1:1 | 2:1:1:1 | 2:1 | 2:1:1 | 3:1:1 | 3:2:1 |
Vessel Quantity | 2 | 3 | 4 | 5 | 3 | 4 | 5 | 6 |
Pumps | ||||||||
Pump Type | Vertical Multi-Stage Centrifugal Pump | Vertical Multi-Stage Centrifugal Pump | Vertical Multi-Stage Centrifugal Pump | Vertical Multi-Stage Centrifugal Pump | Vertical Multi-Stage Centrifugal Pump | Vertical Multi-Stage Centrifugal Pump | Vertical Multi-Stage Centrifugal Pump | Vertical Multi-Stage Centrifugal Pump |
Motor HP / KW | 15 / 11 | 15 / 11 | 25 / 19 | 25 / 19 | 25 / 19 | 40 / 30 | 40 / 30 | 50 / 37 |
System Electrical | ||||||||
Standard Voltage + Amp Draw | 460V, 60Hz, 3PH, 19AF | 460V, 60Hz, 3PH, 19AF | 460V, 60Hz, 3PH, 19AF | 460V, 60Hz, 3PH, 19AF | 460V, 60Hz, 3PH, 19AF | 460V, 60Hz, 3PH, 19AF | 460V, 60Hz, 3PH, 19AF | 460V, 60Hz, 3PH, 19AF |
System Dimensions | ||||||||
Approximate Dimensions G L x W x H (in /cm) | 112 x 35 x 74 / 284 x 89 x 188 | 112 x 35 x 74 / 284 x 89 x 188 | 112 x 35 x 74 / 284 x 89 x 188 | 112 x 35 x 84 / 284 x 89 x 213 | 194 x 41 x 78 / 493 x 104 x 198 | 194 x 41 x 78 / 493 x 104 x 198 | 194 x 41 x 78 / 493 x 104 x 198 | 194 x 41 x 84 / 493 x 104 x 213 |
Approximate Weight (lbs/Kg) | 2130 / 970 | 2450 / 1110 | 3040 / 1380 | 3340 / 1520 | 4100 / 1860 | 4490 / 2040 | 5280 / 2400 | 5640 / 2560 |
Test Parameters: 7,000 TDS Filtered (5–Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 350 psi / 24 bar Operating Pressure, 77°F / 25°C, Recovery as stated, 7.0 pH. Data taken after 60 minutes of operation.
D. Low temperatures and feedwater quality, such as high TDS levels will significantly affect the
systems production capabilities and performance. Computer projections must be run for individual
applications which do not meet or exceed minimum and maximum operating limits for such conditions.
E. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not
exceed recommended permeate flow.
F. Varies with motor manufacturer
G. Does not include operating space requirements.
OPERATING LIMITS E
Design Temperature (°F / °C) | 77 / 25 | Maximum SDI Rating (SDI) | < 3 |
Maximum Feed Temperature (°F / °C) | 85 / 29 | Maximum Free Chlorine (ppm) | 0 |
Maximum Feed Temperature (°F / °C) | 40 / 4.4 | Maximum Hardness (gpg) | 0 |
Maximum Ambient Temperature (°F / °C) | 120 / 49 | Maximum pH (continuous) | 11 |
Minimum Ambient Temperature (°F / °C) | 40 / 4.4 | Minimum pH (continuous) | 2 |
Maximum Feed Pressure (psi / bar) | 85 / 6 | Maximum pH (cleaning 30 minutes) | 13 |
Minimum Feed Pressure (psi / bar) | 45 / 3 | Minimum pH (cleaning 30 minutes) | 1 |
Maximum Piping Pressure (psi / bar) | 400 / 28 | Maximum Turbidity (NTU) | < 1 |
H. System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature.