S3– 4125
Reverse Osmosis System


Product Images

S3– SERIES REVERSE OSMOSIS SYSTEMS

AXEON® S3– Series Reverse Osmosis Systems are engineered and manufactured for seawater applications specifically tailored for capacities ranging from 600 to 2,200 gallons per day. The S3– Series Reverse Osmosis Systems feature a unique and innovative compact design that allows for easy installation in any size area.

The S3 – Series is also equipped with premium components, which include a 316L SS plunger-type pump for high performance, a high grade corrosion resistant aluminum frame, a programmable computer controller with many built-in features and fiberglass membrane housings for durability.


BENEFITS
  • Fully Equipped and Customizable
  • High Quality Components
  • Individually Tested and Preserved
  • Low Operation and Maintenance Costs
  • Easy Maintenance and Servicing
  • Pre-Plumbed, Wired and Assembled
  • 1-Year Limited Warranty

FEATURES
  • S –150 Computer Controller
    • LCD Backlit Display
    • Pre-Treatment Lockout
    • Tank Level Input
    • Pressure Monitoring and Alarm
    • TDS Monitoring
    • Hour Meter
    • Feed Flush
  • High Rejection Seawater Membranes
  • AXEON FRP– Series Membrane Housings
  • AXEON 5-Micron Sediment Pre-Filter
  • Permeate and Concentrate Flow Meters
  • 0-100 psi 316L– SS Glycerin-Filled Filter In Pressure Gauge
  • 0-100 psi 316L– SS Glycerin-Filled Pre–Filter Out Pressure Gauge
  • 0-1500 psi 316L– SS Glycerin-Filled Concentrate Pressure Gauge
  • Plast-O-Matic Feed Solenoid Valve
  • AXEON 316L Stainless Steel Needle Valve
  • 316L SS Feed Low Pressure Switch
  • 316L SS High Pressure Pump Switch
  • CAT® 316L High Pressure Pump
  • TEFC Motor with Thermal Motor Protection
  • Chemical Pump Outlet
  • Powder Coated Aluminum Frame
  • High Pressure 316L Stainless Steel Tubing and Fittings
  • High Pressure Hose with Reusable SS Fittings

OPTIONS AND UPGRADES
  • Booster Pump
  • High Pressure Tank Switch
  • Permeate Divert Valve
  • Fresh Water Flush
  • Ultraviolet Light
  • Wooden Shipping Crate

Notes:

  • 1. All dimensions are given in inches.


ARRAY SPECIFICATIONS
Model Vessel Array Vessel Size Vessel Quantity Membrane Size Membrane Quantity
S3 –1125 1 2540 1 2540 1
S3 – 2125 1:1 2540 2 2540 2
S3 – 3125 1:1:1 2540 3 2540 3
S3 – 4125 1:1:1:1 2540 4 2540 4

SPECIFICATIONS
MODELS S3 –1125 S3 – 2125 S3 – 3125 S3 – 4125
Design
Configuration Single Pass Single Pass Single Pass Single Pass
Feedwater SourceA TDS < 35,000 ppm TDS < 35,000 ppm TDS < 35,000 ppm TDS < 35,000 ppm
Standard Recovery Rate % 10 20 25 36
Rejection and Flow RatesB
Nominal Salt Rejection % 99 99 99 99
Permeate Flow Rate (gpm / lpm) 0.41 / 1.55 0.83 / 3.14 1.25 / 4.73 1.52 / 5.75
Minimum Concentrate Flow Rate (gpm / lpm) 4.20 / 15.90 4.20 / 15.90 4.20 / 15.90 4.20 / 15.90
Connections
Feed FNPT (in) 1/2 1/2 1/2 1/2
Permeate Tubing (in) 3/8 3/8 3/8 3/8
Concentrate Tubing (in) 3/8 3/8 3/8 3/8
Membranes
Membranes Per Vessel 1 1 1 1
Membrane Quantity 1 2 3 4
Membrane Size 2540 2540 2540 2540
Vessels
Vessel Array 1 1:1 1:1:1 1:1:1:1
Vessel Quantity 1 2 3 4
Pumps
Pump Type Plunger Plunger Plunger Plunger
Motor HP / KW 2.50 / 1.85 2.50 / 1.85 2.50 / 1.85 2.50 / 1.85
RPM @ 60Hz (50 Hz) 1725 / 1450 1725 / 1450 1725 / 1450 1725 / 1450
System Electrical
Standard Voltage + Amp Draw 220VAC, 1PH, 11.9AC 220VAC, 1PH, 11.9AC 220VAC, 1PH, 11.9AC 220VAC, 1PH, 11.9AC
System Dimensions
Approximate Dimensions D L x W x H (in /cm) 45.625 x 18 x 26.75 / 115.9 x 45.7 x 67.9 45.625 x 18 x 26.75 / 115.9 x 45.7 x 67.9 45.625 x 18 x 26.75 / 115.9 x 45.7 x 67.9 45.625 x 18 x 26.75 / 115.9 x 45.7 x 67.9
Approximate Weight (lbs/Kg) 145 / 65.77 155 / 70.31 165 / 74.84 175 / 79.38

Test Parameters: 35,000 TDS Filtered (5–Micron), Dechlorinated, Municipal Feedwater, 45 psi / 3.1 bar Feed Pressure, 850 psi / 58.61 bar Operating Pressure, 77°F / 25°C, Recovery as stated, 7.0 pH. Data taken after 60 minutes of operation.

A. Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions.
B. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow.
C. Varies with motor manufacturer
D. Does not include operating space requirements.


OPERATING LIMITS E
Maximum Feed Temperature (°F / °C) 85 / 29 Maximum Turbidity (NTU) < 1
Maximum Feed Temperature (°F / °C) 41 / 5 Maximum Free Chlorine (ppm) 0
Maximum Ambient Temperature (°F / °C) 120 / 49 Maximum Hardness (gpg) 0
Minimum Ambient Temperature (°F / °C) 40 / 4 Minimum pH (continuous) 11
Maximum Feed Pressure (psi / bar) 60 / 4 Minimum pH (continuous) 2
Minimum Feed Pressure (psi / bar) 15 / 1 Minimum pH (cleaning 30 minutes) 13
Maximum Operating Pressure (psi / bar) 1000 / 69 Minimum pH (cleaning 30 minutes) 1
Maximum Feed Silt Density Index (SDI) < 3